HOME

WAN ACCESS PRODUCTS





TEST EQUIPMENT








sales@telinc.com
support@telinc.com


5941 Atkinson Road
Suite B
New Hope, PA 18938
800-257-5110 856-489-0700
Fax: 856-489-1785



TL1016
Equipment Nest

TL1016



16 CSU/DSUs in 4.375" of vertical rack space

256 CSU/DSUs in a standard 70" rack

T-l, E-1 and DDS CSU/DSUs

SNMP, VT100 and DIP switch control

115 VAC, 220 VAC and 48 VDC

The Telinc TL1016 Equipment Nest packs 16 CSU/DSUs in only 4.375" (2.5U) of rack space, 256 in a standard 70" cabinet. It accommodates any combination of Telinc T-l, E-1 and DDS CSU/DSUs, each con- trolled with SNMP, a VT100 terminal or DIP switches. The nest mounts in 19" or 23" racks and is available with single or dual, load-sharing 115 VAC, 220 VAC and 48 VDC power supplies. The CSU/DSUs are also available in standalone form.

SNMP, VT100 and DIP Switch Control

Telinc CSU/DSUs can be controlled with a local or remote VT100 terminal or individually with switches on each CSU/DSU. SNMP control, with an Ethernet interface, is available as an option. The embedded SNMP agent is MIB II-compliant and supports SNMP gets, sets and traps. With SNMP, the TL1016 presents a single IP address for all sixteen CSUs in the nest.

Optional Redundant Power Supplies and Controllers

The equipment nest power supply and controller are packaged together on a single plug-in module. A second module can he added for maximum reliability. The dual supplies operate in a load-sharing mode with either capable of assuming the full load.

The redundancy can be implemented with two AC supplies, two DC supplies or one of each. The common controllers are used only for communication with the remote manager. Failure of one or both of them will not affect operation of the CSU/DSUs.

Midplane Construction

The TL1016 equipment nest employs a midplane design. There are eighteen slots in the front of the nest and eighteen more in the rear. Two of the front and rear slots are used for the power and controller modules. The other sixteen slots are for CSU/DSUs. The products are made up of two-board sets, a CSU/DSU board and an interface board. The CSU/DSU board plugs into the front of the nest and contains the T-l, E-1 or DDS CSU/DSU. The interface board plugs into the rear and contains the interface circuitry and connectors for T-l, E-l, DDS, RS232, RS422, RS530, V.35, etc.

The Telinc midplane approach provides flexibility for change. New interfaces can be added to existing products. New products can use existing interface connections. Products can be inserted and removed without disturbing interface cabling.


 Specifications

The TL1016 equipment nest accommodates Telinc TL3080R, TL3450R, TL3452R, TL3550R, TL3552R and TL3580R T-l, E-1 and DDS CSU/DSUs.


Number of Slots


16 CSUs, 2 power and control

Console Port

Electrical
Mechanical 
RS232, VT100 @ 9600 bps
RJ11 

Ethernet Interface

Electrical
Mechanical
10Base-T
RJ45
Power
90 to 130 VAC, 57 to 63 Hz
210 to 250 VAC, 45 to 55 Hz
48 VDC 100 watts fully loaded 

Dimensions

4.375" (2.5U) H x 19" W x 17" D
(11 cm x 48 cm x 43 cm)

Mounting

19" or 23" with mounting kit
16 nests per 70" cabinet 

Weight

30 lbs (13.6 kg) fully loaded

Operating Temperature

32º to 122ºF, 0º to 50ºC

Relative Humidity

0% to 95%, non-condensing

© Telinc Corporation 2008